|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TOTAL POWER INT'L 120W Single Output Industrial DIN RAIL Power Supply Features : Cooling by free air convection DR-120 series AC input range selectable by switch Protections:Short circuit/Over load/Over voltage/Over temperature Can be installed on DIN rail TS-35/7.5 or 15 UL 508(industrial control equipment)approved LED indicator for power on 100% full load burn-in test Fixed switching frequency at 55KHz 3 years warranty R SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT DR-120-12 12V 10A 0 ~ 10A 120W DR-120-24 24V 5A 0 ~ 5A 120W 80mVp-p 24 ~ 28V 1.0% 0.5% 1.0% DR-120-48 48V 2.5A 0 ~ 2.5A 120W 100mVp-p 48 ~ 53V 1.0% 0.5% 1.0% RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE ADJ. RANGE 12 ~ 14V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION LOAD REGULATION SETUP, RISE, HOLD TIME VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE 0.5% 1.0% 500ms, 70ms, 30ms/230VAC 500ms, 70ms, 30ms/115VAC at full load 88 ~ 132VAC/176 ~ 264VAC by switch 248 ~ 370VDC 47 ~ 63Hz 80% 3.3A/115VAC 2A/230VAC 84% 85% COLD START 30A/115VAC 60A/230VAC <3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 29 ~ 33V 58 ~ 65V 15 ~ 16.5V Protection type : Shut down o/p voltage, re-power on to recover 90 5 (TSW1) 85 5 (TSW1) OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 4) 90 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL508,UL60950-1, TUV EN60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011,EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A 136.8Khrs min. MIL-HDBK-217F (25 65.5*125.2*100mm (W*H*D) 0.79Kg; 20pcs/16.5Kg/1.1CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 120W Single Output Industrial DIN RAIL Power Supply Mechanical Specification DR-120 Case No. 921 series Unit:mm 100 125.2 +V ADJ. 115VAC 230VAC TB1 1 2 3 TB2 1 2 3 4 LED ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Terminal Pin. No Assignment (TB1) Pin No. 1 2 3 Assignment FG AC/N AC/L 6 5.5 35 Terminal Pin. No Assignment (TB2) Pin No. 1,2 3,4 Assignment DC OUTPUT +V DC OUTPUT -V Output Derating Static Characteristics (24V) Ta=25 100 48V 32 28 24 20 16 12 350 300 250 200 150 100 80 80 60 12V,24V 40 20 OUTPUT VOLTAGE (V) 8 -10 0 10 20 30 45 50 60 (VERTICAL) 80 160 85 170 90 180 95 190 100 200 105 210 110 220 115 230 120 240 125 250 130 260 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz OUTPUT RIPPLE (mVp-p) LOAD (%) |
Price & Availability of DR-120-48 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |